Software Auto-Upgrade Failed Due to Open Reports in Period
Some sites have experienced upgrade durations exceeding two hours, causing the process to time out and fail. The root cause is an excessive accumulation of unprocessed data in an open reporting period (Period 3 or 4), which forces the Auto Upgrade engine to restore a disproportionately large dataset before it can proceed. This is generally caused by sites failing to close reports for those periods.
Sites may encounter one of the following errors when attempting an Auto Upgrade:
“E9092 Software auto-upgrade failed due to open reports in Period-4”
“E9093 Software auto-upgrade failed due to open reports in Period-3”
The most likely cause is that the Roll Up DB Reports setting (found under Report > Report Configuration in the Configuration Client) defaults to YES for both Month and Year. This means that the Database (DB) from the Daily report rolls up into the Monthly report. The DB from the Monthly report rolls up to the Yearly report. Sites that do not use monthly (31-day) or yearly (365-day) reports may be unaware that these reports must be closed. Not closing these reports allows data to accumulate into large volumes.
Solution
Option A — Site Does Not Use Monthly or Yearly Period Reports (Recommended)
If the site does not use the affected period reports, perform the following steps:
Log in to Config Client, hover over the Reporting menu, and select Report Configuration.
Select 3 – Month from the Period Configuration pull-down menu.
Set “Roll Up DB Reports” to NO.
Select 4 – Year from the Period Configuration pull-down menu.
Set “Roll Up DB Reports” to NO.
Save the configuration.
From the Point of Sale (POS), navigate to CSR Func, Maintenance Menu, and select Check For VRSD to re-stage the download.
Select Apply Upgrade to start the upgrade process again.
Option B — Site Uses Period Reports
If the site does use the affected period’s reports and wants to preserve the data, follow these steps:
From the POS, navigate to CSR Functions > Reporting Menu.
Select the Close YEARLY Report. This will start to close all period reports in sequence (Shift, Day, Month, Year).
After the Year closes, navigate to CSR Func, Maintenance Menu, and select Check For VRSD to re-stage the download.
Select Apply Upgrade to start the upgrade process again.