Configuring Auxiliary Forecourt POS

Auxiliary Forecourt POS configuration to implement functionality is similar for all supported devices, regardless of the hardware manufacturer.

All system configuration is done through the Commander Configuration Client.

1

Select Managed Modules

Select Tools >> Managed Modules.

2

Select the module

Select Auxiliary Forecourt from the Select Module drop-down menu.

Verifone Commander offers four channels, with each channel supporting up to four devices over four different serial ports.

The following table provides nominal serial configurations settings:

AUXPOS & Wetstock

PetroVend

Baud Rate

4800

9600

Stop Bits

1

1

Data Bits

7

7

Parity Bits

odd

even

Some older PetroVend devices use a baud rate of 1200 bps. The servicer should obtain and confirm correct serial device configuration settings from the Auxiliary POS device installer.

3

Advanced Settings

Select the Auxiliary Forecourt Channel to configure and click [Advanced Settings]. Click the Enable checkbox to activate the Auxiliary Forecourt Channel.

4

Enable the channel

Click the Enable checkbox to activate the Auxiliary Forecourt Channel.

5

Device Type

Select the Device Type:

  • AUXPOS: for devices using PAM protocol, does not include Pump Status Values. (Choose AUXPOS for FMI PIC devices.)

  • PetroVend: for proprietary PetroNet Protocol.

  • Wet Stock: for devices using PAM protocol, includes Pump Status Values.

6

Serial Port Name

Select the Serial Port Name.

Verifone Commander provides 16 available port connections, and is capable of being expanded as needed.

Commander Site Controller serial ports on rear panel

7

Set the serial communication parameters

Select the appropriate Baud Rate.

Select the number of Stop Bits.

Select the number of Data Bits.

Select the Parity Bit setting.

8

Configure Fueling Positions

Click Fueling Positions [Advanced Settings].

Click to select the Fueling Positions to be included.

All fueling positions to be included for Auxiliary Forecourt payment access must be selected.

9

Save

Click Save.

10

Configure Emulated PCTs

Click Emulated PCTs [Advanced Settings].

Installers must coordinate with the Forecourt POS Provider, and match PCT configurations that exist on the PetroVend Fuel Pump Interface.

Select the Emulated PCTs from the four available options: PCT 1 through PCT 4.

11

Save the configuration

Click [Save] in the Channel PCTs selection window.

Click [Save] in the Channel Configuration window.