Communications

If the Auxiliary Forecourt POS device is not communicating as expected, the following basic troubleshooting steps are provided:

Check the serial port LEDs on the front panel of Verifone Commander.

Confirm the red and green LEDs, corresponding to the port(s) configured for the Auxiliary POS, are flashing to indicate a good communication link.

For PetroVend, as an RS-485 interface is used, check the red and green LEDs on the appropriate 485 board in the FCI. These LEDs should also be flashing.

For FMI PIC devices, a null modem cable is required. A straight through serial cable along with a Verifone RJ-45/DB9(F/F) null modem adapter (PN: 13638-02) may also be used.

If the LEDs are not flashing:

  • Check the cables and connections to the Auxiliary POS device to ensure all are properly attached.

  • Verify that the Auxiliary POS device is powered on.

If the device is still not communicating correctly, reset the communication link to the Auxiliary POS device through Verifone Configuration Client. Reset the device by disabling and re-enabling the problematic Auxiliary POS channels via managed modules.

1

Navigate to managed modules

Navigate to Tools >> Managed Modules.

2

Select the module

Select module: Auxiliary Forecourt.

3

Open the channel settings

Select the Auxiliary Forecourt channel and click [Advanced Settings].

4

Disable the channel

Click to deselect the Enable checkbox.

5

Save

Click [Save].

6

Re-enable the channel

Select the Auxiliary Forecourt channel and click [Advanced Settings].

Click to re-select the Enable checkbox.

7

Save again

Click [Save].