PetroNet Protocol

PetroNet Components

Standard PetroNet components consists of the following:

  • Terminal(s) - requires one payment terminal per island; supports multiple fuel dispensers.

  • Controller - one per site, equivalent to Verifone Payment Controller.

  • Fuel Pump Interface - roughly equivalent to Verifone Smart Fuel Controller (SFC), provides the PetroVend system with an interface to the fuel dispensers.

Fuel Pump Interface

The PetroVend Fuel Pump Interface:

  • supports both mechanical and electronic dispensers

  • supports logical groupings of pumps, by type, called Pump Control Terminal(s) (PCTs). Each PCT can include up to eight pumps.

In the Auxiliary Forecourt POS implementation, the PetroVend Fuel Pump Interface is replaced by the Verifone POS System.

Installers must understand how the PetroVend Fuel Pump Interface is configured, and the logical pump assignments per PCT. The Verifone POS System configuration must match the PetroVend PCT configuration.

Controller

The PetroVend Controller regularly polls the fuel dispenser(s) for a system aware reply, but does not query for availability. The PetroVend system has no internal concept of pump reservation, and always proceeds as if the pump is always ready. The only command then sent to the pumps is to turn on the pump, and the submitted command either succeeds or fails based on the fueling position’s readiness status.