Local Area Network Configuration
The LAN needs to be configured for Gilbarco CRIND. In the Gilbarco configuration, the Commander is the CLIENT and the Gilbarco CRIND is the SERVER. The Outdoor EMV DCR IP traffic must be routed from Commander through the network IP of 192.168.31.31. Depending on which device specific IP configuration is selected for the site. Device Specific network routes might need to be added.
Isolated Payment NIC
In Configuration Client, navigate to Initial Setup > Local Area Network Configuration.
Click on Isolated Payment NIC in the Device Specific IP Configuration.
Verify with your network provider if the "Default Route" parameter needs to be checked. If the parameter is checked, then continue with the next steps. If not checked, then skip to the EPS Global Configuration Section.

If Default Route is checked, then add New Route Config to the Device Specific Routes per site.
Route Type: Network
EMV Parameter IP Address (Forecourt > DCR > DCR Position Attributes) with the 4th octet set to 0.
Gateway: 192.168.31.31
Netmask: 255.255.255.0
Save the configuration changes and reboot Verifone Commander.
EPS Global Configuration
The EMV Configuration tab of the EPS Global Configuration screen contains options for both inside and outside EMV use.
Navigate to Configuration Client > Payment Controller > EPS Global Configuration > EMV Configuration.
From the Config Type drop down menu, select OUTSIDE.
In the Terminal Configuration section and from the EMV Enable Status drop down menu, select the parameter CONTACT or CONTACT AND CONTACTLESS.
Select Save.
Fuel and DCR Initialization
After configuring Managed Modules for Fuel and DCR, perform a Fuel and DCR initialization.
Navigate to Configuration Client > Tools > Refresh Configuration.
To initialize Fuel, navigate to Configuration Client > Forecourt > Initialization and then select Fuel.

A message stating Fuel Initialization Successfully Sent displayed. Select Ok.

To initialize the Fuel Driver, navigate to Configuration Client > Forecourt > Initialization and then select Fuel Driver.

A message stating Fuel Driver Initialization Successfully Sent displayed. Select Ok.

To initialize DCR Driver, navigate to Configuration Client > Forecourt > Initialization and then select DCR Driver.

A message stating DCR Driver Initialization Successfully Sent displayed. Select Ok.

EMV Initialization
After Commander has established communications with the Gilbarco FlexPay™ CRIND positions, it will require an EMV Initialization to be performed. This action sends required Gilbarco EMV resource files to the selected CRIND positions.
Navigate to the Configuration Client > Payment Controller > EPS Global Configuration > EMV Initialization.
From the Initialize POP section locate the Available POP List.
For the CRIND(s) requiring initialization, select the required CRIND ID and click the Add >> button to move it to the Selected POP List.
Repeat steps 2 and 3 for any additional CRIND IDs.

When finished selecting POP positions to be initialized, click Save. This performs an EMV POP initialization of the selected CRIND positions.
If another EMV Initialization is required, first perform a Refresh Configuration.
Navigate to Configuration Client > Tools > Refresh Configuration. This updates the Available POP List contents. Repeat the EMV Initialization steps 1 through 5 above.

Verification of Forecourt Status
Use the following steps to verify IP based communications to the DCRs.
Navigate to Configuration Client > Tools > Helpdesk Diagnostics > Forecourt. The DCR Status should appear as "Online." If they are offline, then communications to the DCRs have not been established. Recheck the connections and verify TCP/IP connectivity.