Outdoor EMV Configuration for Wayne iX Pay CAT
Managed Modules
Navigate to Tools > Managed Modules > Current Configuration.
At Host Names, select sitecontroller.
At Select Module, choose the DCR Driver option.
Select the DCR Channel to set up.
For each DCR Channel for EMV, select:
Enable option must be checked.
IP Enabled option must be checked.
Port Name option must remain empty. NOTE: EMV communications is done via the Ethernet port on the Commander, therefore the DCR Channel Port Name will be left blank.
There will be no LED lights for DCR on the front of the Commander since the communications is via the Ethernet port.
DCR Family type selection is Wayne.

Save DCR Driver changes.
Note: If both IP Enabled and Port Name parameters are selected, an error displays when attempting to save the configuration changes.

After completing the DCR Channel set-up, select DCR Positions option and assign CRIND positions to their respective DCR.
DCR Configuration
The following EMV specific parameters are required for each EMV DCR/CRIND position:
Navigate to Configuration Client > Forecourt > DCR.

Select DCR Position Attributes.
Under EMV Parameters section for each of the Selected EMV DCR Position:
Enable EMV must be checked.
IP Address must be left blank.
Port must be left blank.
For NFC Mode, select one of the following: * Contactless Disabled -- Contactless (including Mobile Payments) is not being used at the DCR. * Contactless MSD Enabled -- Use only if Contactless EMV is not supported or not certified for Gilbarco dispensers. This mode uses the Mag-Stripe Data (MSD). * Contactless EMV Enabled -- Use if Contactless EMV is supported and network certified for Gilbarco dispensers. This mode uses the chip data on the card.
In the Other Parameters section, select the appropriate parameter configurations and click Save.
DCR Keys Configuration
DCR key mapping is necessary for the PIN pad to respond correctly to customer key presses.
Navigate to Configuration Client > Forecourt > DCR Keys.
Create a DCR Keys layout by clicking on Add for Wayne DCRs below.
Wayne DCRs:
Label: Wayne EMV
#Rows: 4
#Columns: 5

Select Assign Positions and Select DCR Position(s) to all the DCRs and click Save.

Click Save at DCR Keys Configuration.

Navigate to Configuration Client > Tools > Refresh Configuration.